水泵产品管路能量损失如何计算
来源:上海民泉
发布日期:2013/1/21
水泵产品管路能量损失如何计算
水泵产品管路能量损失如何计算?我们以每100米直管损失为例(表中为新铸铁直管,旧管损失加倍)
管径(mm)
|
25 |
38 |
50 |
65 |
75 |
100 |
125 |
150 |
175 |
200 |
250 |
300 |
流量(L/S) |
1 |
3.27 |
3.5 |
0.8 |
|
|
|
|
|
|
|
|
|
2 |
13 |
14 |
3.1 |
0.8 |
0.4 |
|
|
|
|
|
|
|
4 |
|
55 |
13 |
3.2 |
1.6 |
0.4 |
|
|
|
|
|
|
6 |
|
|
29 |
7.1 |
3.3 |
0.8 |
0.23 |
|
|
|
|
|
8 |
|
|
|
13 |
5.9 |
1.3 |
0.4 |
0.16 |
|
|
|
|
10 |
|
|
|
20 |
9.6 |
2.1 |
0.63 |
0.26 |
0.11 |
|
|
|
15 |
|
|
|
|
21.6 |
6.8 |
1.3 |
0.58 |
0.27 |
0.13 |
|
|
20 |
|
|
|
|
|
8.6 |
2.7 |
1.1 |
0.5 |
0.26 |
0.07 |
|
25 |
|
|
|
|
|
13 |
4.1 |
1.6 |
0.74 |
0.37 |
0.12 |
|
30 |
|
|
|
|
|
19.4 |
5.9 |
2.3 |
1.05 |
0.53 |
0.18 |
0.07 |
40 |
|
|
|
|
|
|
10.7 |
4.2 |
1.9 |
0.93 |
0.3 |
0.12 |
50 |
|
|
|
|
|
|
|
6.4 |
2.9 |
1.5 |
0.48 |
0.19 |
60 |
|
|
|
|
|
|
|
9.4 |
4.3 |
2.1 |
0.68 |
0.27 |
70 |
|
|
|
|
|
|
|
|
5.8 |
2.9 |
0.93 |
0.37 |
80 |
|
|
|
|
|
|
|
|
7.7 |
3.7 |
1.2 |
0.49 |
90 |
|
|
|
|
|
|
|
|
9.6 |
4.7 |
1.5 |
0.6 |
100 |
|
|
|
|
|
|
|
|
|
6.1 |
1.9 |
0.76 |
110 |
|
|
|
|
|
|
|
|
|
7.2 |
2.3 |
0.9 |
120 |
|
|
|
|
|
|
|
|
|
8.5 |
2.8 |
1.1 |
130 |
|
|
|
|
|
|
|
|
|
|
3.3 |
1.3
|
阀和弯管的损失系数:
阀及弯管折合直管长度(每个)
|
种类 |
折合直管直径倍数 |
备注 |
全开闸阀 |
12 |
未畅开加倍 |
标准弯管 |
25 |
|
逆止阀 |
100 |
|
底阀 |
100 |
部分堵塞加倍
|
表格中的数据如何解读?如我们的离心泵产品,要求流量20L/S,管路口径DN100,设计长度50米,4个弯管,1个逆止阀,那么管路损失为多少?
查表我们可以得到每100米直管损失8.6米,现在管路为50米,摩擦损失为4.3米;每个标准弯管损失为25*100=2500mm,4个弯管相当于10米直管(10000mm),所以摩擦损失为0.86米;一个逆止阀损失也是0.86米;所以该管路摩擦损失10.32米。当然在设计时需要预留一定的余量。
以上方法适合管道离心泵产品,隔膜泵产品,自吸泵产品,潜水泵产品等等。
一定管路直径有他的大承载量限制,让我们来看一看:
一定管路直径之大流量限制
|
管路直径 |
大流量 |
大流速 |
管路直径 |
大流量 |
大流速 |
(mm) |
(L/S) |
(m/s) |
(mm) |
(L/S) |
(m/s) |
25 |
1 |
2.04 |
125 |
30 |
2.44 |
38 |
2.5 |
1.69 |
150 |
43 |
2.45 |
50 |
4.17 |
2.12 |
175 |
60 |
2.49 |
65 |
6.67 |
2.01 |
200 |
83.3 |
2.69 |
75 |
10 |
2.26 |
250 |
133.3 |
2.72 |
100 |
18.4 |
2.33 |
300 |
192 |
2.71
|
欢迎探讨指正,感谢你对上海民泉的支持,谢谢!~